RITLOK угловые фитинги
POSITIONABLE SAE MALE ELBOW RLS-UP

Connects fractional tube to SAE Straight thread boss
Installation Instructions
SAE and ISO parallel thread fittings
1. Lubricate O-ring with a lubricant compatible with the O-ring material and the system fluid.
2. Back the locknut out.
3. Finger-tighten the fitting into the straight thread boss until the metal backup washer contacts the face of the boss.
4. Position the fitting by backing it out until the fitting end is positioned in the desired direction.
No more than one turn backing out.
5. Hold the fitting in the direction and wrench-tighten the locknut until the washer contacts the face of the boss.
POSITIONABLE 45° SAE MALE ELBOW (PREVIOUSLY RLBS-U) RLBS-UP)

Connects fractional tube to SAE straight thread boss
POSITIONABLE SAE MALE RUN TEE(PREVIOUSLY RTRS-U) RTRS-UP

Connects fractional tube to SAE straight thread boss
POSITIONABLE MALE ELBOW ISO PARALLEL THREAD RLM-GP

Connects fractional tube to ISO parallel thread

Connects metric tube to ISO parallel thread
MALE PIPE WELD CONNECTOR RCW

Connects fractional tube to pipe
Connects metric tube to pipe

MALE PIPE WELD ELBOW RLW

Connects fractional tube to pipe

TUBE SOCKET WELD CONNECTOR RCSW

Connects fractional tubes

CONNECTS FRACTIONAL TUBES
RITLOK weld ends are constructed to SCH. 80 or greater.
1. Remove the nut and ferrules from the RITLOK port.
.This protects the nut and ferrules from weld heat.
2. Cover the RITLOK port threads with a protective device such as RITLOK Plug (DP).
.This protects threads and sealing surface on the RITLOK port.
.Finger-tighten the DP to use it many times.
3. Tack weld at four positions 90 degree apart.
.This holds thefitting in alignment and concentricity.
4. Complete the welding.
5. Remove the protective device and replace the nut and ferrules.
TUBE SOCKET WELD ELBOW RLSW

Connects fractional tubes

WELDING BULKHEAD UNION RBUW

Connects fractional tubes